renzhenning 发表于 2012-7-14 15:03:27

这个问题困扰了一天了求解决啊

在radioss里面做静力分析总是出现这种错误提示:材料属性
都已经设置好了(图片是材料属性的设置)
************************************************************************
**                                                                  **
**                                                                  **
**                        OptiStruct 10.0                           **
**                                                                  **
**                  Design and Optimization Software                  **
**                   from Altair Engineering, Inc.                  **
**                                                                  **
**                                                                  **
**               ProfessionalSP1 (Build 7601)RZN-PC               **
**      2 CPU:Intel(R) Core(TM)2 Duo CPUP7350@ 2.00GHz      **
**                        CPU speed2000 MHz                         **
**                     932 MB RAM,4085 MB swap                      **
**                                                                  **
** Build tag: 0466938_5333O00_Ci3242M-000      14000                  **
************************************************************************
**COPYRIGHT (C) 1996-2009               Altair Engineering, Inc.**
** All Rights Reserved.Copyright notice does not imply publication. **
** Contains trade secrets of Altair Engineering, Inc.               **
** Decompilation or disassembly of this software strictly prohibited. **
************************************************************************


*** OptiStruct defaults set from:
   install config file: D:\Altair\hw10.0/hwsolvers/hwsolver.cfg


*** ERROR # 1237 ***
CSHEAR element number 25873 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25874 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25875 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25876 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25877 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25878 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25879 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25880 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25881 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25882 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25883 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25884 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25885 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25886 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25887 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25888 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25889 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25890 references
        a missing or invalid property number 4.

*** ERROR # 1237 ***
CSHEAR element number 25891 references
        a missing or invalid property number 4.

*** More of ERROR messages # 1237 were suppressed...

*****************
Too many error messages. Aborting run.
Current limit is 10000. Use "MSGLMT" control card to change this value.


************************************************************************
Following error/warning messages appeared too many times
and were suppressed:
    1237
Total of 9980 repeat error message(s) were suppressed.
To see more messages use "MSGLMT" control card in the data or config file.

renzhenning 发表于 2012-7-14 16:36:03

求高手解答啊!模型附件

cssuzhicai 发表于 2012-7-16 09:33:17

应该是属性定义有问题

hanjixing 发表于 2012-7-17 16:08:34

本帖最后由 hanjixing 于 2012-7-17 16:21 编辑

求几何模型,改了属性还是不行,坐等高手。。。加我秋秋:270928052 共同商讨如何解决

lowelljiayou 发表于 2012-7-17 18:36:57

MSGLMT 这个卡片是控制你的错误,警告,信息的数量的.默认的是1000,修改一下这个卡片的值看看

hanjixing 发表于 2012-7-18 08:17:28

lowelljiayou 发表于 2012-7-17 18:36 static/image/common/back.gif
MSGLMT 这个卡片是控制你的错误,警告,信息的数量的.默认的是1000,修改一下这个卡片的值看看 ...

翻译谁都会啊。。

zy19900304 发表于 2012-7-18 18:50:23

属性设置错误,楼主改下属性看看

renzhenning 发表于 2012-7-27 13:30:30

hanjixing 发表于 2012-7-17 16:08 static/image/common/back.gif
求几何模型,改了属性还是不行,坐等高手。。。加我秋秋:270928052 共同商讨如何解决
...

是不是单元类型没有定义呢 我最后在elem type里面update一下就没有上面的问题了!

zhousy 发表于 2012-8-29 11:43:26

你设置的可能是3d单元网格的属性,但你的网格是2D的就会出现这种错误,请把2d网格删除就好了

zy19900304 发表于 2012-8-29 20:01:19

你的属性问题已经帮你解决,但是weld连接也要改,建议每个weld重新建立,或者改用rigid body

hhj502066714 发表于 2012-10-30 19:48:23

可以去看看OUT里面的具体提示
页: [1]